Vue de la page 38
21
Part 2: Interfacing and Configuring
T
DSU
T
DH
T
SH
T
SL
Direction
Step
T
DC
T
CHL
T
CHL
Channel
A
Channel B
Direction Change
T
SH
T
SL
T
DC
T
SH
T
SL
T
DC
Step Up
Step Down
STEP/DIRECTION TIMING
QUADRATURE TIMING
UP/DOWN TIMING
Figure 2.4.3: Clock Input Timing Characteristics
Clock Input Timing
Symbol Parameter
Type and Value
Step/Direction Step Up/Down Quadrature Units
T
DSU
T Direction Set Up 50 nS min
T
DH
T Direction Hold 100 nS min
T
SH
T Step High 100 100 nS min
T
SL
T Step Low 100 100 nS min
T
DL
T Direction Change 200 200 nS min
T
CHL
T Channel High/Low 400 nS min
F
SMAX
F Step Maximum 5 5 MHz Max
F
CHMAX
F Channel Maximum 1.25 MHz Max
F
ER
F Edge Rate 5 MHz Max
Table 2.4.1: Input Clocks Timing Table